Marque:SCHNEIDER ELECTRIC
Ref Product:EZ9R36225
Ref Mcmining:SCEZ9R36225
| Description | |
| Residual current circuit breaker (RCCB), Easy9, 2P, 25A, AC type, 30mA |
|
| EZ9R36225 |
|
| This product is a Easy9 residual current circuit breaker
(RCCB). It is a 2P circuit breaker with 25A In rated current, a sensitivity
of 30mA with a AC type protection class. This product protects against
electrical shock by direct or indirect contact and fire hazards. It also has
protection against fire hazards due to persistent earth fault current. This
product has a positive contact indications with fault tripping indication on
the front panel by the position of the handle (0-I engraved). This is dedicated
for residential and small commercial buildings market segment. This product
is compliant with IEC 61008-1 standard. The (Im/IΔm) rated breaking and
making short circuit capacity is 500A. The (Inc/IΔc) conditional rated
short circuit current is 6000A. The mechanical endurance is going up to 5000
cycles and electrical endurance going up to 2000 cycles. The Ue operational
voltage is 230VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated
impulse withstand voltage is 4kV. The frequency is 50Hz or 60Hz. It is DIN
rail mountable. The width in 9mm pitches is 4. The product color is light
grey (RAL7035). The dimensions are (W) 36mm x (H) 82mm x (D) 72mm. It has an
IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40
once in modular enclosure. The operating temperature is from -5°C to 60°C.
The storage temperature is from -40°C to 85°C. |
|
| Specifications |
|
|
Main |
|
| Range of product |
Easy9 |
| Product or component type |
Residual current circuit breaker (RCCB) |
| Device short name |
Easy9 RCCB |
| Poles |
2P |
| Neutral position |
Left |
| [In] rated current |
25 A |
| network type |
AC |
| Earth-leakage sensitivity |
30 mA |
| Earth-leakage protection time delay |
Instantaneous |
| Earth-leakage protection class |
Type AC |
| Rated breaking and making capacity |
500 A |
| Rated conditional short-circuit current |
Easy9 MCB: 6000 A 25 A |
| Complementary |
|
| Device location in system |
Outgoer |
| Network frequency |
50/60 Hz |
| [Ue] rated operational voltage |
230 V AC 50/60 Hz |
| Residual current tripping technology |
Voltage independent |
| [Ui] rated insulation voltage |
440 V AC |
| [Uimp] rated impulse withstand voltage |
4 kV |
| Surge current |
250 A |
| Contact position indicator |
Yes |
| Control type |
Toggle |
| Mounting mode |
Clip-on |
| Mounting support |
DIN rail |
| Comb busbar and distribution block compatibility |
Top: YES |
| Connection pitch |
18 mm between phases |
| 9 mm pitches |
4 |
| Height |
82 mm |
| Width |
36 mm |
| Depth |
72 mm |
| Colour |
Grey (RAL 7035) |
| Mechanical durability |
5000 cycles |
| Electrical durability |
AC: 2000 cycles 230 V AC 50/60 Hz |
| Connections - terminals |
Tunnel type terminal (top or bottom) 1…35 mm² rigid |
|
Tunnel type terminal (top or bottom) 1…25 mm² flexible |
|
| Tightening torque |
3.5 N.m top or bottom |
| Environment |
|
| Standards |
IEC 61008-1 |
| Product certifications |
CE |
| IP degree of protection |
IP20 |
| Pollution degree |
2 conforming to IEC 61008-1 |
| Tropicalisation |
2 |
| Relative humidity |
95 % at 55 °C |
| Ambient air temperature for operation |
-5…60 °C |
| Ambient air temperature for storage |
-40…85 °C |