Catalog /electricity / modulaires-circuit-breaker / Product details
Product details Print
...
Residual current circuit breaker (RCCB), Easy9, 4P, 25A, AC type, 300mA

Marque:SCHNEIDER ELECTRIC

Ref Product:EZ9R66425

Ref Mcmining:SCEZ9R66425

Type:
Add to cart
Description

Residual current circuit breaker (RCCB), Easy9, 4P, 25A, AC type, 300mA

EZ9R66425

This is a Easy9 residual current circuit breaker (RCCB). It is a 4P circuit breaker with In rated current of 25A, AC type protection class and a 300mA earth leakage sensitivity. This product protects against electrical shock by indirect contact and fire hazards. It also has protection against fire hazards due to persistent earth fault current. This product has a positive contact indications with fault tripping indication on the front panel by the position of the handle (0-I engraved). This is dedicated for residential and small commercial buildings market segment. This product is compliant with IEC 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 500A. The (Inc/IΔc) conditional rated short circuit current is 6000A. The electrical endurance is up to 2000 cycles. The mechanical endurance is up to 5000 cycles. The Ue operational voltage is 400VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The product color is light grey (RAL7035). The dimensions are (W) 72mm x (H) 82mm x (D) 72mm. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C.



Specifications

Main

Range of product

Easy9

Product or component type

Residual current circuit breaker (RCCB)

Device short name

Easy9 RCCB

Poles

4P

Neutral position

Left

[In] rated current

25 A

network type

AC

Earth-leakage sensitivity

300 mA

Earth-leakage protection time delay

Instantaneous

Earth-leakage protection class

Type AC

Rated breaking and making capacity

500 A

Rated conditional short-circuit current

Easy9 MCB: 6000 A 25 A

Complementary

Device location in system

Outgoer

Network frequency

50/60 Hz

[Ue] rated operational voltage

400 V AC 50/60 Hz

Residual current tripping technology

Voltage independent

[Ui] rated insulation voltage

440 V AC

[Uimp] rated impulse withstand voltage

4 kV

Surge current

250 A

Contact position indicator

Yes

Control type

Toggle

Mounting mode

Clip-on

Mounting support

DIN rail

Comb busbar and distribution block compatibility

Top: YES

Connection pitch

18 mm between phases

9 mm pitches

8

Height

82 mm

Width

72 mm

Depth

72 mm

Colour

Grey (RAL 7035)

Mechanical durability

5000 cycles

Electrical durability

AC: 2000 cycles 400 V AC 50/60 Hz

Connections - terminals

Tunnel type terminal (top or bottom) 1…35 mm² rigid

Tunnel type terminal (top or bottom) 1…25 mm² flexible

Tightening torque

3.5 N.m top or bottom

Environment

Standards

IEC 61008-1

Product certifications

CE

IP degree of protection

IP20

Pollution degree

2 conforming to IEC 61008-1

Tropicalisation

2

Relative humidity

95 % at 55 °C

Ambient air temperature for operation

-5…60 °C

Ambient air temperature for storage

-40…85 °C